UNIFOLD Gutter Lining System
-
Gutter Lining Components Specification Listing
Gutter Components Specification Listing - Back To Top
To customise and complete the model specification please select the items as required from the
following components list
SUMPS: Factory fabricated and sealed and supplied as part of a section of Unifold gutter.
Install fully in accordance with manufacturers instructions.
SIDE BOXES: Factory fabricated and sealed and supplied as part of a section of Unifold gutter. Install fully in accordance with manufacturers instructions.
SECTION CHANGE: factory fabricated and sealed to include a small section of each gutter. Install fully
in accordance with manufacturers instructions
EXPANSION / CONTRACTION JOINT: Manufactured as an integral part of a Unifold section to be installed between two fixed points i.e.:- two outlets / one outlet and at the stop-end / corner or junction. To be fitted fully in accordance with manufacturers instructions.
System drawing number 1024
SIPHONIC OUTLET SECTIONS: Manufactured as an integral part of a Unifold section. To be fitted fully
in accordance with manufacturers instructions.
System drawing number 1026
CORNERS: factory fabricated and sealed. To be fitted fully in accordance with manufacturers
instructions
System drawing number 1027
TEES: Factory fabricated and sealed. To be fitted fully in accordance with manufacturers instructions. System drawing number 1028
PERMANENT TIE-OFF ASSEMBLY: Supplied in component kit form to permanently terminate Unifold within the length of the gutter i.e.:- at the party line of two buildings sharing the same gutter. Install fully in accordance with manufacturers instructions. System drawing number 1017
PVCU OVERFLOW UNITS 50mm DIAMETER x 300mm LONG: Supplied as a factory fabricated unit. Install fully in accordance with manufacturers instructions.
System Drawing number 1035
SNORKEL OVERFLOW UNITS (For flashing existing overflows): Supplied as a factory manufactured unit. Install fully in accordance with manufacturers instructions.
System drawing number 1025
SNORKEL OVERFLOW UNITS (For the insertion of new overflows): Supplied as factory fabricated unit. Install fully in accordance with manufacturers instruction.
System drawings may be obtained from Ampteam on request.
General Specification and Maintenance Instructions - Back To Top
GENERAL SPECIFICATION &
MAINTENANCE
INSTRUCTIONS
UNIFOLD gutter systems are manufactured
from a composite sheet consisting of a
synthetic rubber membrane fully bonded to a
galvanised steel sheet using a high pressure
bonding process.
The resulting bond is unaffected by the
extremes of heat, cold or moisture normally
experienced on roofs and buildings.
The lining and its metal substrate form a
composite sheet giving optimum wet life
performance with the strength, workability
and handling qualities of steel.
UNIFOLD employs CARLISLE SYNTEC "SURESEAL" EPDM which is a fully cured,
single ply synthetic roofing membrane made
of ethylene, propylene, diene, terpolymer
which is renowned for its very long term
stability and life span in excess of 50 years. "Sureseal" EPDM membrane is covered by
British Board of Agrément Certificate No
92/2791, copies of which are available on
request.
TECHNICAL SPECIFICATION
- MATERIALS & COMPONENTS
1. CARLISLE SYNTEC "SURESEAL"
EPDM MEMBRANE
A Black ELASTOMERIC MEMBRANE with a
good combination of high elasticity and
tensile strength.
Temperature stability from -45 degree
centigrade to + 130 degrees centigrade
retaining elasticity at low temperatures and
resistance to temperature shocks up to 250
degrees centigrade.
SURESEAL has excellent resistance to U.V
radiation and ozone concentration base.
2. STEEL SUBSTRATE.
HD Galvanised mild
steel to E.N.10142-1991– FE PO2G / BS
2989/1982 Z2/G275, 0.7mm thickness.
To provide further protection for the
galvanised steel substrate, it is provided, as
a minimum specification, with a heat cured,
high performance polyester topcoat over a
corrosion resistant primer.
UNIFOLD STANDARD COMPONENT
LENGTH - 2800mm
3. SOLE BOARD (closed cell Insulation Board)
Extruded Polystyrene "STYROFOAM" I.B board
(or similar approved) minimum density 28kg/m3
and thermal conductivity value 0.033 w/mk.
Insulation thickness to suit gutter bolt head/stud
intrusion height and thermal requirements.
4. JOINTS: mechanical means utilising butt
straps join Unifold gutter systems. There are
two types of butt straps. Type 1 - fixed with
A.D.68 Blind rivets. Used for normal
installations
Type 2 – Clip joint – Used for difficult access
situations
Both types are sealed with P40 polyurethane
mastic which is permanently flexible. Mastic
service temperature, - 40 degrees centigrade
to + 80 degrees centigrade (dry) & + 50
degrees centigrade (wet).
Following installation joints are further
protected by an EPDM membrane strip,
covering the whole joint and fixings which is
cold vulcanised in position. Normal width of
membrane strip is 150mm.
5. OUTLETS:
1) E.P.D.M Elastoform factory fabricated in a
spigot format to suit specified down pipe
sizes. Positioned through a cut hole into the
Unifold gutter and spliced (cold vulcanised)
into position in accordance with splicing
instructions.
2) EPDM Sureseal Metal/Membrane factory
fabricated in a spigot format to suit specified
downpipe sizes. Used to replace corroded
outlets or to provide new outlets. Also used
as a security point each side of an expansion
joint for Unifold.
All outlets can be manufactured to suit any existing outlet type
6. FABRICATION: Items to complement the
system such as Sumps, Side boxes, section
changes are fabricated and sealed in the
factory. These items are most often
manufactured within a small section of
Unifold to enable the simplest of operations
to install.
7. HANDLING & PROTECTION: EPDM can
easily withstand without damage, limited foot
traffic and light concentration loads associated
with installation and maintenance. All
maintenance or repair crews should be
advised that the gutters are EPDM membrane
lined and that care should be exercised to
prevent damage. Any possible damage should
be reported immediately. Ampteam Ltd
recommends that a log is kept of all roof top
activity.
To avoid damage by sharp objects during
roofing work programmes and particularly
where the gutter is to be used as a walkway
or work platform during these programmes
then the gutter should first be cleaned in the
prescribed manner, and then adequately
protected by boards.
On work completion and removal of boards
the gutter must be inspected for damage.
8. MAINTENANCE (Please see Unifold Care & Maintenance Guide available on request
from Ampteam)
A) The roofs of all buildings should be inspected
at regular intervals as part of a planned
maintenance programme, particularly where
the building is in or near a wooded area,
subject to high winds, or there are industrial
pollutants which may accumulate in the
surface water run-off.
B) CLEANING
1. EPDM gutter should be fully swept out and
cleaned by hosing down and swept with a
soft broom.
2. Shovels or metal scrapers should never be
pushed or pulled along the surface of the
EPDM.
3. Following sweeping, the EPDM surface
should be inspected for signs of surface
damage particularly at joints or seams.
4. Remove, clean and replace all balloon
gratings. Exercise care to prevent damage
to EPDM membrane outlets.
C) DAMAGE REPAIR: EPDM can be repaired throughout its
extensive life using the following procedure.
1. Clean around the damaged area.
2. When repairing membrane which has been
in service for some time, it is necessary to
remove accumulated dirt by first scrubbing
the membrane with a brush and warm
soapy water.
3. After rinsing with clean water and drying, a
second cleaning is required using a splice
primer to prepare and reactivate the
membrane.
4. Cut a patch of membrane that extends
minimum 80mm on each side of the boundaries of the damaged area.
5. Round all corners of the repair piece.
6. Install the splice fully in accordance with
splicing procedures.
9. APPROVED CONTRACTORS: Our network of approved installation
contractors are available to effect repairs,
clean gutters and to inspect for damage
should this service be required.
|